CFQYB - REDUCERS, R7 K 54

  • MSDS: CFQYB
  • Manufacturer: SHERWIN WILLIAMS CO
  • Product Name: REDUCERS, R7 K 54
  • National Stock Number: 8010-01-255-5928
Product Identification

Product ID:REDUCERS, R7 K 54
MSDS Date:03/08/1996
FSC:8010
NIIN:01-255-5928
MSDS Number: CFQYB

Responsible Party
SHERWIN-WILLIAMS CO
101 PROSPECT AVE NW
CLEVELAND, OH 44115
US

Emergency Phone: 216-566-2917

Info Phone: 216-566-2902

Cage: 54636

Contractor
SHERWIN-WILLIAMS CO THE
CLEVELAND, OH 44115-1042 US

Telephone: 800-251-2486/216-566-2242

Cage: 54636

Ingredients

7.1

CAS: 100-41-4

RTECS: DA0700000

Fraction By Weight: 4%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/125 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


5.9

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 22%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/150 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


44.0

CAS: 64-17-5

RTECS: KQ6300000

Fraction By Weight: 23%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


2-HEPTANONE; (METHYL ISOBUTYL KETONE) (SARA 313) (CERCLA)

CAS: 108-10-1

RTECS: SA9275000

Fraction By Weight: 51%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM/75 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


CONSULT NFPA CODE. USE APPRVD BONDING &

RTECS: 9999999ZZ


ONLY TO APPRVD CONTRS W/COMPLETE & APPROP LABELING.

RTECS: 9999999ZZ


INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING AND

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: IRRIT OF EYES, SKIN & RESP SYS.
MAY CAUSE NERV SYS DEPRESS. EXTREME OVEREXP MAY RSLT IN UNCON &
POSS DEATH. SIGNS & SYMPS OF OVEREXP: HDCH, DIZZ, NAUS & LOSS OF
CONSCIOUSNESS ARE INDICATIONS OF EXCESS EXPOS TO VAPS/SPRAY MISTS.
REDNESS & ITCH/BURNING SENSATION MAY INDICATE EYE/EXCESS SKIN
EXPOS.(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: CHRONIC: PRLNG OVEREXP TO SOLV INGS
MAY CAUSE ADVERSE EFTS TO LIVER, URINARY SYS, REPRO SYS. RPTS HAVE
ASSOC RPTD & PRLNG OVEREXP TO SOLVS W/PERM BRAIN & NERV SYS DMG.
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

First Aid

First Aid:INHAL: REMOVE FROM EXPOS. RESTORE BRTHG. KEEP WARM & QUIET.
SKIN: WASH AFFECTED AREA THORO W/SOAP & WATER. REMOVE CONTAM CLTHG
& LAUNDER BEFORE REUSE. EYES: FLUSH W/LGE AMTS OF WATER FOR AT
LEAST 15 M IN. GET MED ATTN. INGEST: NEVER GIVE ANYTHING BY MOUTH
TO AN UNCON PERS. DO NOT INDUCE VOMIT. GIVE SEVERAL GLASSES OF
WATER. SEEK MED ATTN.

Fire Fighting

Flash Point:55.0F,12.8C
Lower Limits:1.0%
Upper Limits:19.0%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFFECTIVE. IF WATER IS USED, FOG NOZZ ARE
PREF. WATER MAY BE USED TO COOL CLSD (SUP DAT)
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CONTRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. APPLICATION TO HOT (SUP DAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE ONLY W/ADEQ VENT. AVOID BRTHG VAP
& SPRAY MIST. AVOID CONT W/SKIN & EYES. KEEP AWAY FROM HEAT,
SPARKS, & OPEN FLAME.
Other Precautions:VAPS WILL ACCUM READILY & MAY IGNITE EXPLO. DURING
USE & UNTIL ALL VAPS ARE GONE: KEEP AREA VENTILATED; DO NOT SMOKE;
EXTING ALL FLAMES, PILOT LIGHTS & HEATERS; TURN OFF STOVES, ELEC
TOOLS & APPLIANCE S, & ANY OTHER SOURCES OF IGNIT. (ING 6)

Exposure Controls

Respiratory Protection:IF PERSONAL PROTECTION CANNOT BE CONTROLLED
BELOW APPLICABLE LIMITS BY VENTILATION, WEAR A PROPERLY FITTED
ORGANIC VAPOR/PARTICULATE RESPIRATOR APPROVED BY NIOSH FOR
PROTECTION AGAINST MATERIALS LISTE D IN INGREDIENTS SECTION.
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPTABLE IF EXPOS IS MAINTAINED
BELOW APPLIC EXPOS LIMITS. REFER TO OSHA STDS (SUP DAT)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC: CONTRS TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO
WHEN EXPOSED TO EXTREME HEAT. EXPLO HAZ: SURF REQUIRES SPECIAL
PREC. DURING EMER CNDTNS OVEREXP TO DECOMP PRODS MAY CAUSE A HLTH H
AZ. SYMPS MAY NOT BE IMMED APPARENT. OBTAIN MED ATTN. VENT:
1910.94, 1910.107, 1910.108.

Chemical Properties

Boiling Pt:B.P. Text:>132F,>56C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.81
VOC Grams/Liter:6.75
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
MONOXIDE.

Disposal

Waste Disposal Methods:WASTE MAY BE HAZ AS DEFINED UNDER RCRA 40 CFR
261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERMINE APPLIC EPA
HAZ WASTE NUMBERS. INCIN IN APPRVD FACILITY. DO NOT INCIN CLSD
CONTR. DISP OF I/A/W FED , STATE, & LOC REGS REGARDING POLLUTION.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.